Every system is hydraulically designed, code-verified, commissioned by our engineers, and backed by full AMC support.
Internal & external hydrant ring mains, electric/diesel/jockey pump sets, landing valves, and hose reels — IS 3844, IS 9668, NBC Part 4 compliant.
Wet pipe, dry pipe, and pre-action automatic sprinkler systems for industrial and commercial buildings — IS 15105 and NFPA 13 compliant.
FM200, CO₂, and inert gas (Argon/Inergen) for server rooms, data centres, and control rooms — NFPA 2001 and IS 15493 compliant.
Addressable and conventional panels, smoke, heat, CO, and flame detectors, manual call points, and voice evacuation — IS 2189, NBC Part 4, NFPA 72.
High-pressure fine water mist for turbine halls, heritage buildings, hospitals, and data centres — effective fire suppression with minimal water damage.
High-velocity spray for transformers, turbines, and cable tunnels — rapid suppression, cooling, and emulsification. IS 15105 and NFPA 15 compliant.
Medium-velocity spray for cable trays, conveyors, and general industrial surfaces — IS 8633 and NFPA 15 compliant.
Fixed and portable detection for LEL, H₂S, CO, LPG, and oxygen monitoring in refineries, oil & gas plants, and industrial facilities.
IP and analogue CCTV for perimeter security, fire monitoring, and industrial surveillance — integrated with fire alarm and access control systems.
Zone-based voice announcements and alarm tones integrated with the fire alarm system for automatic evacuation messaging — NBC 2016 Part 4 compliant.
We verify, calculate, and commission every system to the applicable national or international standard — and support clients through fire NOC approval.
IS 3844, IS 9668, IS 2189, IS 15105, IS 8633, IS 15493 — all applicable BIS fire safety standards for each system type.
NFPA 13, 14, 15, 72, 75, and 2001 — applied where required by client specifications or project scope.
OISD 116, 117, and 118 for fire protection in petroleum, oil & gas, and process industry facilities across India.
NBC 2016 Part 4 — mandatory fire safety rules for commercial and industrial buildings, with full CFO fire NOC support.
Each fire protection system is matched to the hazard type, environment, and compliance requirement — not a one-size-fits-all approach.
Hydrant systems, HVWS for furnace bays, sprinklers for production halls, addressable detection in MCC rooms.
Foam suppression for tank farms, HVWS for transformers, gas detection, and plant-wide hydrant ring mains to OISD norms.
FM200 or inert gas suppression, VESDA early-warning smoke detection, and addressable alarms to NFPA 75 and NFPA 2001.
Transformer HVWS, cable tunnel deluge, turbine hall suppression, and control room gas suppression to CEA and NFPA standards.
Wet pipe sprinklers, voice evacuation PA, medical gas-area detection, and addressable fire alarms to NBC Part 4 and NABH requirements.
Automatic sprinklers, hydrant coverage, voice evacuation, and addressable detection for shopping malls, warehouses, and office buildings.